NI LabVIEW 2025 Q3 | 3.4 Gb
NI is now part of Emerson's new Test & Measurement business group has released LabView 2025 Q3 is a programming environment used to create applications using the G programming language.
LabVIEW 2025 Q3 Features and Changes - Released June 2025
Introducing Nigel, AI Advisor
Nigel is your trusted test and measurement advisor, trained on the NI platform and ready to help when you need it. Get VI design advice, learn LabVIEW concepts, and more!
Troubleshoot VIs Using New Debug Window
The new Debug Window added in LabVIEW 2025 Q3 combines probe and breakpoint management in a single location, and replaces the Probe Watch window and Breakpoint Manager window. The Debug Window lists breakpoints and probes for all VIs in memory, and allows you to add, remove, rename, highlight, and export data for probes and breakpoints. You can also use the window to enable and disable breakpoints, switch probe styles, and create custom probes. You can use the Debug Window to customize the window appearance, as well as if probe values appear directly on wires in your VI block diagram during execution [Idea submitted by NI Discussion Forums member Citabria].
Added Logging for Unwired Errors
LabVIEW 2025 Q3 gives you the option to record unwired errors in a log file, independent of whether you use the Automatic Error Handling dialog to report them.
Select All Text Using Ctrl+A
LabVIEW 2025 Q3 enables use of the keyboard shortcut Ctrl+A to select all text whenever editing a text field, including in labels, string controls, and dialogs
Quickly Open Files Using Ctrl+Shift+O
LabVIEW 2025 Q3 adds the Quick Open dialog, which can be opened using the keyboard shortcut Ctrl+Shift+O. The dialog displays recently-opened files that you can open, as well as all files in any project you have open.
Preserve Values by Default When Placing Diagram Disable Structures
In LabVIEW 2025 Q3, when placing a Diagram Disable Structure to enclose a section of code, LabVIEW will match output tunnels with input tunnels to wire values through in the Enabled frame by default. If LabVIEW is not able to find the source for a refnum or LabVIEW class output tunnel, the tunnel will not be configured with Use Default if Unwired.
Added Context Help Notes Section for VIs
LabVIEW 2025 Q3 adds a Notes section to the Context Help for VIs to highlight settings that might be of interest when reviewing VI block diagrams. This section includes:
- Reentrancy, if the VI is configured for shared clone reentrant execution or preallocated clone reentrant execution.
- Execution Priority, the VI is configured to a priority other than normal priority.
- Preferred Execution System, if the VI is configured to a Preferred Execution System other than same as caller or standard.
Added Context Help Notes Section for Call Library Function Node
LabVIEW 2025 Q3 adds a Notes section to the Context Help for Call Library Function Nodes. This section includes:
- Function prototype
- Library name or path
Left-Aligned Text for Improved Readability in Diagram Objects
In LabVIEW 2025 Q3, the text in some block diagram objects is left-aligned, for improved readability. The objects changed are:
- Bundle by Name
- Unbundle by Name
- Unbundle/Bundle Elements on In Place Element Structure
- Event Structure Data Nodes
- Get Waveform Components
- Build Waveform
- Get Digital Waveform Components
- Build Digital Waveform
- Get Digital Data Components
- Build Digital Data
Use LabVIEW Command Line Interface Without Enabling VI Server TCP Port
LabVIEW 2025 Q3 allows users to use the LabVIEW Command Line Interface (CLI) without enabling the VI Server TCP Port. If users do not enable the port, the CLI configures LabVIEW on a per-operation basis so it can execute the specified operation. These per-operation configurations do not persist after the operation executes. All existing workflows that previously enabled the VI Server TCP port (with the default or user-defined port number) will continue to work as they did in previous releases.
Generate VI Comparison Reports with the LabVIEW Command Line Interface
LabVIEW 2025 Q3 adds a new command to the LabVIEW Command Line Interface for generating VI Comparison reports. Use the CreateComparisonReport operation name along with the names of the two VIs you want to compare to output an HTML, XML, Word, or text file summarizing the differences between the files.
Support for .NET (Core) 8.0 Objects in Register Event Callback Function
The Register Event Callback function now supports handling .NET 8.0 objects in LabVIEW 2025 Q3.
Note :Added Support for Windows Long Paths
The .NET Container and building .NET assemblies are not yet supported with .NET 8.0.
LabVIEW 2025 Q3 adds support for Windows long paths.
Added Support for Additional Data Types in Array Export Commands
In LabVIEW 2025 Q3, the Export Data to Clipboard and Export Data to Excel commands in the right-click menu of arrays are enabled for arrays of paths as well as one-dimensional arrays of clusters containing only numeric, string, and path elements.
Added Vertical Scrollbar for Free Labels
In LabVIEW 2025 Q3, free labels have a Visible Items » Vertical Scrollbar option in the right-click menu to show and hide a vertical scrollbar.
Note :Changed Default Option for Compiled Code in Source Distributions
If you create a VI with the vertical scrollbar shown on a free label and open it in LabVIEW 2025 Q1, the label will not function correctly.
In LabVIEW 2025 Q3, new source distributions on desktop targets will use the compiled code setting saved in each source file by default. Previously, the default was to embed compiled code in all source files
3063044 VI Comparison Report Can Show Incorrect Text Value Change for Caption. In some cases, a caption text value change can have the "from" and "to" strings in the wrong order.
063044 Python Node With Object Refnum Input Returns Error 1744 After Repeated Calls. When using a Python Node with a Python object refnum as an input, LabVIEW returns error 1744 after 1,048,576 calls.
2972983 Select .NET Core Constructor Dialog Incorrectly Reports No Public Constructors For Classes Not Part of Any Namespace. If you select a class that is not part of any namespace in the Select .NET Core Constructor dialog, the message This class contains no public constructors is displayed, even if the class does contain public constructors.
3005689 LabVIEW Does Not Detect When LabVIEW Class Should Be Broken Because Its Private Data Includes Set or Map That Contains the Class
3006536 .NET Refnum Control Is Missing Select .NET Core Class Right-Click Menu
3008439 Constructor Node for .NET Core Does Not Include Exception Details with Error 1172
3039297 Simple Numeric Constant Created Instead of Ring When Creating Constant from Ring Typed Terminal of LabVIEW Class Property Node
3066513 Calls to .NET Core Methods With Multiple Return Values Do Not Return Values to Output ParametersIf you call a .NET Core method that uses the out keyword to have multiple return values, LabVIEW does not correctly return those values.
3066525 .NET Core Enumerations Are Treated As References. LabVIEW can pass numeric values to and from .NET Framework properties and method parameters, but when using .NET Core properties and methods, you must use references instead. This limitation requires you to write extra code to get and set values on the reference.
3073490 LabVIEW Crashes When Outputs on .NET Core Property or Invoke Nodes Are Unwired
3077738 LabVIEW Sometimes Crashes With .NET Core Methods Using Arrays of Strings
3144001, 3166958 Vulnerabilities CVE-2025-2633 and CVE-2025-2634. Fixed Vulnerabilities CVE-2025-2633 and CVE-2025-2634.
2941475 Text Entry Renders Incorrectly in Table Cells with Centered Text
2963459 Python Node Returns Error 1667 When Module Path Contains Unicode Characters
2974910 Configuration Dialog Missing for Fixed Point Shared Variable
3126088 Web Service URL Limited to 512 Characters
2918538 Compile Error When Using Not A Number/Path/Refnum Function with Dynamic Data
2922757 Cannot Edit Enum Array Element By Holding Ctrl Key and Clicking the Element
2930247 Mass Compile Slower Because LabVIEW Does Not Save VIs in LVAddons. When you mass compile VIs that reference VIs in the version-independent location on the computer (LVAddons), the VIs in LVAddons are compiled multiple times, which causes the mass compile to take longer to complete.
3003728 LabVIEW Sometimes Crashes After Reordering Controls on Page of Tab Control
3011141 Tree Alternating Row Color is Incorrect on First Row if Column Headers Not Visible
3029109 VI Window Sometimes Positioned Incorrectly When VI Properties for Window Position and Panel Size Are Set. When a VI has both Window Position and Panel Size configured to non-default values in its Properties, the run-time position of the window can be incorrect.
3040552 LabVIEW Sometimes Crashes After Replacing Tab Control with Another Tab Control
3042977 Probe Display of XML Reference Does Not Display Correct Value
3044350 LabVIEW Does Not Report Save Compatibility Issue with Splitter Bars When Saving to Versions Earlier than 19.0
3045969 LabVIEW Crashes When Executing Replace No Attributes Method on Tab Control
3050230 Debug Write.vim Erroneously Displays Last Element of Non-string Array At Beginning of Debug String
3058541 Some Mixed Signal Graph Plots Do Not Display Plot Area Foreground Image. When a Mixed Signal Graph has the "Plot Images:Front" property set, only the first plot displays the image.
3160785 No Value Change Event Fired After Deleting Array Element With Ctrl+Del Keyboard Shortcut
3161234 Reentrant VIs Sometimes Lose Reentrancy Setting Unexpectedly in Project Configured With a Save Version Earlier Than the Editor Version
3162353 Controls In Built Applications Do Not Receive Mouse Wheel Event If Ctrl Key Is Also Pressed
3168519 LabVIEW Does Not Detect Save Incompatibility for Concatenate Strings in Save Versions Prior to 21.0
1554661 Error 1055 in VISL_findDependentVISvr.vi when Building Executable. Error 1055 sometimes occurs when building an EXE with the LabVIEW DSC Module installed.
3036893 Vulnerability CVE-2025-7361. Fixed Vulnerability CVE-2025-7361. LabVIEW no longer supports Code Interface Nodes unless the configuration file contains EnableCodeInterfaceNodes=True.
063044 Python Node With Object Refnum Input Returns Error 1744 After Repeated Calls. When using a Python Node with a Python object refnum as an input, LabVIEW returns error 1744 after 1,048,576 calls.
2972983 Select .NET Core Constructor Dialog Incorrectly Reports No Public Constructors For Classes Not Part of Any Namespace. If you select a class that is not part of any namespace in the Select .NET Core Constructor dialog, the message This class contains no public constructors is displayed, even if the class does contain public constructors.
3005689 LabVIEW Does Not Detect When LabVIEW Class Should Be Broken Because Its Private Data Includes Set or Map That Contains the Class
3006536 .NET Refnum Control Is Missing Select .NET Core Class Right-Click Menu
3008439 Constructor Node for .NET Core Does Not Include Exception Details with Error 1172
3039297 Simple Numeric Constant Created Instead of Ring When Creating Constant from Ring Typed Terminal of LabVIEW Class Property Node
3066513 Calls to .NET Core Methods With Multiple Return Values Do Not Return Values to Output ParametersIf you call a .NET Core method that uses the out keyword to have multiple return values, LabVIEW does not correctly return those values.
3066525 .NET Core Enumerations Are Treated As References. LabVIEW can pass numeric values to and from .NET Framework properties and method parameters, but when using .NET Core properties and methods, you must use references instead. This limitation requires you to write extra code to get and set values on the reference.
3073490 LabVIEW Crashes When Outputs on .NET Core Property or Invoke Nodes Are Unwired
3077738 LabVIEW Sometimes Crashes With .NET Core Methods Using Arrays of Strings
3144001, 3166958 Vulnerabilities CVE-2025-2633 and CVE-2025-2634. Fixed Vulnerabilities CVE-2025-2633 and CVE-2025-2634.
2941475 Text Entry Renders Incorrectly in Table Cells with Centered Text
2963459 Python Node Returns Error 1667 When Module Path Contains Unicode Characters
2974910 Configuration Dialog Missing for Fixed Point Shared Variable
3126088 Web Service URL Limited to 512 Characters
2918538 Compile Error When Using Not A Number/Path/Refnum Function with Dynamic Data
2922757 Cannot Edit Enum Array Element By Holding Ctrl Key and Clicking the Element
2930247 Mass Compile Slower Because LabVIEW Does Not Save VIs in LVAddons. When you mass compile VIs that reference VIs in the version-independent location on the computer (LVAddons), the VIs in LVAddons are compiled multiple times, which causes the mass compile to take longer to complete.
3003728 LabVIEW Sometimes Crashes After Reordering Controls on Page of Tab Control
3011141 Tree Alternating Row Color is Incorrect on First Row if Column Headers Not Visible
3029109 VI Window Sometimes Positioned Incorrectly When VI Properties for Window Position and Panel Size Are Set. When a VI has both Window Position and Panel Size configured to non-default values in its Properties, the run-time position of the window can be incorrect.
3040552 LabVIEW Sometimes Crashes After Replacing Tab Control with Another Tab Control
3042977 Probe Display of XML Reference Does Not Display Correct Value
3044350 LabVIEW Does Not Report Save Compatibility Issue with Splitter Bars When Saving to Versions Earlier than 19.0
3045969 LabVIEW Crashes When Executing Replace No Attributes Method on Tab Control
3050230 Debug Write.vim Erroneously Displays Last Element of Non-string Array At Beginning of Debug String
3058541 Some Mixed Signal Graph Plots Do Not Display Plot Area Foreground Image. When a Mixed Signal Graph has the "Plot Images:Front" property set, only the first plot displays the image.
3160785 No Value Change Event Fired After Deleting Array Element With Ctrl+Del Keyboard Shortcut
3161234 Reentrant VIs Sometimes Lose Reentrancy Setting Unexpectedly in Project Configured With a Save Version Earlier Than the Editor Version
3162353 Controls In Built Applications Do Not Receive Mouse Wheel Event If Ctrl Key Is Also Pressed
3168519 LabVIEW Does Not Detect Save Incompatibility for Concatenate Strings in Save Versions Prior to 21.0
1554661 Error 1055 in VISL_findDependentVISvr.vi when Building Executable. Error 1055 sometimes occurs when building an EXE with the LabVIEW DSC Module installed.
3036893 Vulnerability CVE-2025-7361. Fixed Vulnerability CVE-2025-7361. LabVIEW no longer supports Code Interface Nodes unless the configuration file contains EnableCodeInterfaceNodes=True.
LabVIEW (Laboratory Virtual Instrument Engineering Workbench) is a graphical programming language that uses icons instead of lines of text to create applications. In contrast to text-based programming languages that use instructions to determine the order of program execution, LabVIEW uses dataflow programming. In data flow programming, the flow of data through the nodes on the block diagram determines the execution order of the VIs and functions. VIs, or virtual instruments, are LabVIEW programs that imitate physical instruments. In LabVIEW, you build a user interface by using a set of tools and objects. The user interface is known as the front panel. After you build the front panel, you add code using graphical representations of functions to control the front panel objects. You add this graphical code, also known as G code or block diagram code, to the block diagram. The block diagram somewhat resembles a flowchart. The block diagram, front panel, and graphical representations of code compose a VI.
Introduction to the LabVIEW+ Suite
We’re excited to announce the release of the NI LabVIEW+ Suite. It’s a suite of LabVIEW, plus, more NI software that provides purpose-built tools for automating measurement, analysis, and test. The software works together to save you time.
Emerson is a global technology and software company providing innovative solutions for the world’s essential industries. Through its leading automation portfolio, including its majority stake in AspenTech, Emerson helps hybrid, process and discrete manufacturers optimize operations, protect personnel, reduce emissions and achieve their sustainability goals.
(October 11, 2023) – Emerson has announced it has closed its acquisition of NI (National Instruments), a leading provider of software-connected automated test and measurement systems. The acquisition of NI advances Emerson’s position as a global automation leader and expands its opportunity to capitalize on key secular trends like nearshoring, digital transformation, and sustainability and decarbonization. NI brings a portfolio of software, control and intelligent devices that is expected to accelerate Emerson’s revenue growth aligned to its 4-7% through the cycle organic growth target.
Owner: Emerson
Product Name: NI LabVIEW
Version: 2025 Q3 (version 25.3.0)
Supported Architectures: x64
Website Home Page : www.ni.com
Languages Supported: english
System Requirements: Windows *
Size: 3.4 Gb
Please visit my blog
Added by 3% of the overall size of the archive of information for the restoration
No mirrors please
Added by 3% of the overall size of the archive of information for the restoration
No mirrors please